ECC Digital kVp Meter, Electronic Control Concepts 815 & 815L
Measures kVp, Waveform & Exposure Time
The 815 is capable of measuring kVp Waveform, and exposure time. The unit is self resetting, and automatically detects AC or DC x-ray currents, minimizing the possibility of inaccurate readings. The Model 815 is battery operated, user-friendly, and has a two year warranty. Applications include verification of peak x-ray voltage, constancy checks, calibration of x-rays, and quality assurance measurement of exposure time. The unit is also used for half value layer determination, troubleshooting and repair of x-rays, and quality control.
Features- Easy to use
- No need to set for AC / DC
- Self-resetting
- Measures kVp and exposure time simultaneously
- kVp is noninvasive
- AC and DC x-rays
- High accuracy
- Measures kVp, & exposure time
- Battery operated
- One year warranty
- Compact size
- Durable ABS plastic case
- Custom carrying case option
- Typical Applications
- Measurement of exposure
- Verification of peak x-ray voltage
- Constancy checks
- X-ray calibration
- Quality assurance
- Measurement of X-ray exposure time
- Half Value Layer determination
- Troubleshooting and repair of X-rays
- Measures the peak x-ray accelerating voltage from tungsten x-ray generators.
- Direct Measurement of peak kV from the x-ray head, simply place 815(L) in beam and take x-ray.
- Push Mode button to display Exposure Time.
- Indicates x-ray waveform type - e.g. Half-wave, Full-wave or DC / 3 Phase.
- Flexible with many x-rays including dental, radiographic and fluoroscopic x-rays.
- Large display readable from outside x-ray room.
- Alphanumeric display provides easy to understand status and error messages.
Low Range Model 815L
The low range version of the kVp meter boasts the flexibility to provide precision at low kVp operation. The low range option is perfect for digital x-rays as well as dental and fluoroscopy machines, which typically operate at lower kV settings. The low range 815L can measure kVp as low as 40 kV and has increased current sensitivity to operate dependably down to 5mA at 50 kV. The low range models are optimized at lower currents and operates up to 115 kV at 100 mA. Contact Supertech for more information and pricing.
kVp Specifications | |
Range |
815: 45 to 125 kV 815L: 40 to 115 kV |
kVp Accuracy | 2% 1 kV, at 25 to 100 mA for 815, at 10 to 50 mA for 815L 18 to 42 cm from head, for Tungsten target x-ray tube with 1.5 mm Al equivalent filtration |
Exposure Time Accuracy | 1% 2 millisecond (1/5 to 2 sec) Minimum exposure time is 100 milliseconds |
Minimum Exposure Time (kVp Measurement) |
100 millisec - High Speed 200 millisec - High Resolution Mode |
Minimum Current (mA) | 7 mA at 50 kV, 10 cm from x-ray source (Also depends on focus / collimating) |
General Specifications for 815 | |
Display | 0.4"(10.2mm) Liquid Crystal, 8 Character Alphanumeric |
Power | 4 AA Batteries accessible from bottom of case, Low Battery Indicator |
Battery Life | 48 hours continuous, typically 9 months of normal use |
Controls/Indicators |
ON/OFF Switch: Illuminated push-button with
green power-on indication MODE Switch: Momentary push-button 8 Character Liquid Crystal Display |
Physical Size |
150 x 120 x 58.5 mm 5.9 x 4.7 x 2.3 inches Weight: 0.7 kg (1.5 lb) |
Optional Accessories | |
800CC | Padded Cordura Carrying Case |
800HC | Hard Shell Carrying Case |